Panel Verification
Check that the fire alarm control panel is powered on and functioning properly.
Verify that all alarm signals are communicating correctly with the monitoring station.
Ensure that all annunciator panels are operational and displaying the correct information.
Device Testing
Test all smoke detectors, heat detectors, and manual pull stations to ensure they are functioning properly.
Check that all notification appliances, such as strobes and horns, are activating when the alarm is triggered.
Verify that all duct detectors and beam detectors are properly calibrated and detecting smoke or heat as intended.
System Integration
Test the integration of the fire alarm system with other building systems, such as HVAC and access control.
Ensure that all elevators are programmed to respond appropriately in the event of a fire alarm.
Verify that all fire doors and dampers are closing as intended when the alarm is triggered.
Documentation Review
Review all record drawings and as-built documents to ensure they accurately reflect the installed fire alarm system.
Verify that all required permits and approvals have been obtained for the installation of the fire alarm system.
Ensure that all testing and inspection reports are completed and documented according to local fire code requirements.
Final Inspection
Conduct a final walkthrough of the building to ensure that all devices are installed in the correct locations and functioning properly.
Verify that all wiring is properly labeled and terminated according to the manufacturer's specifications.
Obtain sign-off from the building owner or representative that the fire alarm system has been accepted and is ready for use.
Conduct a thorough inspection of all battery backup systems to ensure they are operational and providing sufficient power in the event of a power outage
Test the communication pathways of the fire alarm system, including phone lines, internet connections, and cellular backup, to ensure reliable transmission of alarm signals
Verify that all fire alarm system components are properly grounded and bonded to prevent electrical interference or malfunctions
Check for any potential sources of false alarms, such as dust or debris near detectors, and address any issues promptly
Test the functionality of any remote annunciators or control panels to ensure they can effectively monitor and control the fire alarm system
Evaluate the effectiveness of the fire alarm system's evacuation procedures, including the sound levels of notification appliances and the clarity of evacuation instructions
Verify that all system software and firmware are up to date and functioning properly to ensure optimal performance and compatibility with other building systems