A detailed Air Cooled Transformer SEMI ANNUAL preventive maintenance checklists 1. Visual Inspection

Visual Inspection

  • Look for cracks, dents, or deformation.
  • Check for any loose or missing screws.
  • Assess the overall integrity of the housing.
  • Examine painted surfaces for flaking or discoloration.
  • Look for any signs of rust on exposed metal.
  • Document areas needing protective coatings.
  • Check for tight seals around access points.
  • Verify that no covers are missing.
  • Test the latch or fasteners for functionality.
  • Remove any loose materials or trash.
  • Check for vegetation or obstructions.
  • Ensure clear pathways for maintenance access.
  • Inspect for oil stains or puddles.
  • Check hoses and connections for signs of wear.
  • Mark areas needing immediate attention.
  • Check for dirt, debris, or foreign objects.
  • Ensure airflow is unobstructed.
  • Clean any clogged areas as necessary.
  • Check for wear, tears, or degradation.
  • Ensure materials are securely attached.
  • Replace damaged insulation as needed.
  • Check all grounding points for tightness.
  • Inspect for rust or corrosion on connectors.
  • Ensure proper grounding path continuity.
  • Inspect wiring insulation for melting.
  • Look for discoloration on nearby surfaces.
  • Identify components showing signs of heat stress.
  • Check that all safety labels are present.
  • Ensure text is clear and readable.
  • Replace faded or damaged labels.
  • Inspect vents for blockages or restrictions.
  • Verify airflow through ventilation openings.
  • Clean any obstructed pathways.
  • Check bolts and screws for tightness.
  • Inspect supports for any damage.
  • Replace any worn or damaged hardware.
  • Check for nests or droppings.
  • Inspect for gnaw marks on insulation or wiring.
  • Implement pest control measures if necessary.
  • Inspect for cracks or abrasions.
  • Check for proper securing of wiring.
  • Replace damaged wiring as needed.
  • Check for cracks or bends in blades.
  • Clean dust buildup from cooling fins.
  • Ensure fans are functioning correctly.
  • Use a level to check transformer alignment.
  • Adjust mounting as necessary.
  • Ensure all connections are aligned properly.
  • Check for proximity of other equipment.
  • Inspect for any structural damage nearby.
  • Ensure clear space for maintenance access.

Electrical Connections

Cooling System

Operational Testing

  • Inspect all indicator lights for proper functionality.
  • Verify that all meters are displaying expected readings.
  • Check for any flickering or abnormal color changes in lights.
  • Ensure all indicators are clean and unobstructed for visibility.
  • Connect the transformer to a known load condition.
  • Monitor performance metrics such as voltage and current.
  • Assess stability and response to load changes.
  • Document any anomalies during the load test.
  • Use calibrated thermometers to check temperature at key points.
  • Compare readings against manufacturer specifications.
  • Look for hotspots or unusual temperature gradients.
  • Record temperature data for trend analysis.
  • Log voltage, current, and temperature readings systematically.
  • Include date and time for each recorded parameter.
  • Ensure records are kept in a safe, accessible location.
  • Use standard forms for consistency in data collection.
  • Check that all cooling fans are running smoothly.
  • Listen for unusual noises that may indicate issues.
  • Ensure airflow is unobstructed and adequate for cooling.
  • Confirm that fan controls are responding correctly.
  • Listen carefully for any grinding or rattling noises.
  • Feel for excessive vibrations on the transformer casing.
  • Investigate any irregularities immediately to prevent damage.
  • Document any findings for further analysis.
  • Use a multimeter to accurately measure voltage levels.
  • Compare findings against specified operational limits.
  • Document all measurements, noting any irregularities.
  • Report any deviations to maintenance personnel.
  • Manually test relays and breakers to ensure they trip as designed.
  • Monitor performance during normal and fault conditions.
  • Check settings against manufacturer specifications.
  • Document the results of the assessment.
  • Use an earth resistance tester to check grounding integrity.
  • Verify that resistance values are within safe limits.
  • Inspect all grounding connections for corrosion or wear.
  • Document the grounding test results for records.
  • Use a harmonic analyzer to measure output harmonics.
  • Compare results against regulatory compliance limits.
  • Document any excessive harmonics for further investigation.
  • Report findings to ensure compliance with specifications.
  • Use a megohmmeter to test insulation resistance.
  • Record resistance values for both primary and secondary windings.
  • Compare results with manufacturer specifications.
  • Investigate any low resistance readings immediately.
  • Test all alarms for audible and visual functionality.
  • Verify that monitoring systems are accurately displaying data.
  • Check backup systems for proper operation.
  • Document the status of each auxiliary device.
  • Obtain the latest manufacturer specifications for reference.
  • Compare operational data with specifications systematically.
  • Identify any performance discrepancies and document them.
  • Prepare a report for maintenance review.
  • Gradually increase load while monitoring performance.
  • Record voltage, current, and temperature at each load level.
  • Assess the transformer's stability and response.
  • Document findings for future reference.