A detailed Escalator MONTHLY preventive maintenance checklists

1. Visual Inspection

2. Mechanical Components

  • Check for unusual noises during operation.
  • Observe alignment with the escalator's frame.
  • Ensure smooth operation without jerks or hesitations.
  • Verify that the drive system components are securely fastened.
  • Inspect for fraying or excessive wear.
  • Ensure proper lubrication is applied where necessary.
  • Look for signs of rust or corrosion.
  • Check tension levels and adjust if needed.
  • Check for any signs of overheating.
  • Listen for abnormal sounds indicating wear.
  • Ensure lubrication is applied according to specifications.
  • Test for smooth rotation without binding.
  • Activate the brake system to check for immediate engagement.
  • Listen for any unusual sounds during operation.
  • Ensure the brake releases smoothly after activation.
  • Inspect brake components for wear or damage.
  • Check that all lights are operational.
  • Replace any burned-out bulbs immediately.
  • Ensure brightness meets safety standards.
  • Clean lenses for optimal visibility.
  • Look for cracks, chips, or significant wear.
  • Check for proper alignment with the escalator track.
  • Ensure step treads are securely attached.
  • Test for smooth operation during movement.
  • Ensure comb plates are flush with the steps.
  • Check for any gaps or misalignments.
  • Tighten any loose fasteners.
  • Inspect for signs of wear or damage.
  • Check for consistent movement without binding.
  • Ensure handrail tension is adequate.
  • Inspect for wear or fraying.
  • Lubricate track if needed for smooth operation.
  • Remove any accumulated debris or obstructions.
  • Check drainage systems for functionality.
  • Inspect for signs of water damage.
  • Ensure access to the pit is clear.
  • Inspect panels for cracks or damage.
  • Ensure all panels are securely fastened.
  • Check for any gaps that could pose a risk.
  • Replace any damaged panels immediately.
  • Inspect chains for wear or damage.
  • Ensure correct tension is maintained throughout.
  • Check for signs of rust or corrosion.
  • Lubricate chains as per manufacturer’s guidelines.
  • Check for cracks, bends, or rust.
  • Ensure all structural components are securely attached.
  • Inspect welds and joints for integrity.
  • Look for any misalignments that could affect operation.
  • Test each safety switch for proper operation.
  • Ensure no obstructions are present around switches.
  • Inspect wiring for wear or damage.
  • Replace any faulty switches immediately.
  • Listen for grinding or rattling sounds.
  • Check for oil leaks around the gearbox.
  • Inspect motor mounts for stability.
  • Ensure all connections are tight and secure.
  • Observe the start for abrupt movements.
  • Check stopping distance for accuracy.
  • Ensure no jerks are felt during acceleration.
  • Test multiple start-stop cycles for consistency.
  • Inspect all bolts and screws for tightness.
  • Check for signs of rust on components.
  • Ensure all fasteners are compliant with specifications.
  • Replace any corroded parts as necessary.
  • Ensure buttons are easily reachable.
  • Test each button for immediate response.
  • Check for any obstructions around buttons.
  • Inspect for wear or damage to the button mechanism.
  • Test the leveling system during operation.
  • Ensure steps align flush with landings.
  • Check for any delays or irregularities.
  • Inspect hydraulic systems for proper function.

3. Electrical Systems

  • Look for illuminated warning lights.
  • Record any error messages displayed.
  • Ensure all indicators function correctly.
  • Clean the panel if necessary.
  • Activate the start function and observe.
  • Ensure the escalator starts smoothly.
  • Stop the escalator and confirm it halts immediately.
  • Test multiple cycles for consistency.
  • Press the emergency stop button.
  • Confirm the escalator halts immediately.
  • Release the button and check reset function.
  • Document any issues encountered.
  • Inspect all visible wiring for frays.
  • Check connections for corrosion or looseness.
  • Look for signs of overheating.
  • Ensure all connections are secure.
  • Manually block the sensors to test response.
  • Ensure the escalator stops immediately.
  • Check for any error messages post-test.
  • Clean sensor areas to ensure clear operation.
  • Check the battery charge level.
  • Test the backup system under load.
  • Inspect connections for corrosion.
  • Replace batteries if nearing end of life.
  • Run the escalator at various speeds.
  • Monitor for any irregular speed fluctuations.
  • Document speed readings against manufacturer specifications.
  • Adjust settings as necessary.
  • Verify that all indicators light up correctly.
  • Test each indicator's responsiveness to escalator movement.
  • Replace any non-functioning bulbs.
  • Document any discrepancies.
  • Inspect circuit breakers for tripped states.
  • Check fuses for any signs of damage.
  • Test reset functionality on breakers.
  • Replace any faulty components.
  • Listen for unusual sounds during operation.
  • Check for excessive heat on the motor casing.
  • Look for signs of wear or damage.
  • Lubricate moving parts if necessary.
  • Perform a full operational test of the escalator.
  • Monitor for any control anomalies.
  • Check response times for commands.
  • Document any operational issues.
  • Inspect all connections for tightness.
  • Identify any corroded terminals.
  • Clean and tighten as needed.
  • Replace any damaged connectors.
  • Simulate a power failure to test lighting.
  • Ensure lights activate and illuminate properly.
  • Check battery backup for charge.
  • Document any failures.
  • Compare diagrams against installed systems.
  • Update any discrepancies found.
  • Ensure easy access to current diagrams.
  • Store updated diagrams in a designated location.
  • Create a detailed report of findings.
  • Include photos of any issues.
  • Categorize anomalies by severity.
  • Submit for review and action.

4. Safety Features

  • Activate each safety device individually.
  • Listen for audible alerts or indicators.
  • Check for proper alignment and responsiveness.
  • Document any faults for immediate repair.
  • Test intercom or emergency call buttons.
  • Verify clear audio and visual signals.
  • Check connection to central monitoring system.
  • Record any issues for follow-up.
  • Activate emergency lights to test functionality.
  • Ensure lighting illuminates all necessary areas.
  • Replace any non-functioning bulbs or fixtures.
  • Log results for maintenance records.
  • Ensure escalator is on a slight incline.
  • Observe operation during load and no load.
  • Check for smooth engagement and disengagement.
  • Report any malfunction immediately.
  • Inspect areas around shut-off switches.
  • Remove any obstructions or hazards.
  • Verify signage indicating switch locations.
  • Ensure switches are easily reachable.
  • Activate each safety device individually.
  • Listen for audible alerts or indicators.
  • Check for proper alignment and responsiveness.
  • Document any faults for immediate repair.
  • Test intercom or emergency call buttons.
  • Verify clear audio and visual signals.
  • Check connection to central monitoring system.
  • Record any issues for follow-up.
  • Activate emergency lights to test functionality.
  • Ensure lighting illuminates all necessary areas.
  • Replace any non-functioning bulbs or fixtures.
  • Log results for maintenance records.
  • Ensure escalator is on a slight incline.
  • Observe operation during load and no load.
  • Check for smooth engagement and disengagement.
  • Report any malfunction immediately.
  • Inspect areas around shut-off switches.
  • Remove any obstructions or hazards.
  • Verify signage indicating switch locations.
  • Ensure switches are easily reachable.
  • Test each emergency stop button.
  • Check for immediate cessation of operation.
  • Ensure buttons are clearly marked and accessible.
  • Document any malfunctioning buttons.
  • Inspect all safety signs for clarity.
  • Clean any signs that are dirty or obscured.
  • Replace any damaged or faded signage.
  • Confirm compliance with safety standards.
  • Simulate an overload condition safely.
  • Observe the escalator's response to overload.
  • Ensure it stops or reverses as designed.
  • Document test results for review.
  • Monitor escalator speed during operation.
  • Verify that speed stays within safety limits.
  • Check for alerts on speed deviation.
  • Record findings for maintenance logs.
  • Check each tread for wear or damage.
  • Remove any debris or objects present.
  • Ensure treads have proper grip and traction.
  • Report any issues needing repair.
  • Check for loose or damaged handrails.
  • Ensure smooth movement along the full length.
  • Lubricate if necessary for optimal function.
  • Document any repairs needed.
  • Conduct a thorough visual inspection.
  • Remove any hazards or debris immediately.
  • Check surrounding area for potential risks.
  • Maintain a clean and safe environment.
  • Inspect barriers for cracks or breaks.
  • Ensure panels are securely attached.
  • Look for signs of rust or corrosion.
  • Report any damage for repair.
  • Apply a load to the escalator.
  • Activate the brake system to test response.
  • Check for smooth engagement and disengagement.
  • Record operational status for safety compliance.

5. Cleaning

  • Use a soft-bristle brush to dislodge debris.
  • Apply a suitable cleaning solution to the steps and handrails.
  • Wipe surfaces with a clean cloth, ensuring no residue remains.
  • Rinse thoroughly with water to remove any cleaning agents.
  • Remove any accumulated dirt or debris from the pit.
  • Check for water accumulation and dry if necessary.
  • Inspect for loose components or signs of wear.
  • Ensure proper drainage is clear and functional.
  • Remove any dust and debris from surfaces and equipment.
  • Inspect for any blockages around motors and wiring.
  • Ensure that all tools and materials are stored properly.
  • Verify that ventilation is not obstructed.
  • Conduct a thorough visual inspection around the escalator.
  • Collect and dispose of any litter or foreign objects.
  • Check the area for any hazards that could affect safety.
  • Report any significant hazards to maintenance personnel.
  • Use a soft-bristle brush to dislodge debris.
  • Apply a suitable cleaning solution to the steps and handrails.
  • Wipe surfaces with a clean cloth, ensuring no residue remains.
  • Rinse thoroughly with water to remove any cleaning agents.
  • Remove any accumulated dirt or debris from the pit.
  • Check for water accumulation and dry if necessary.
  • Inspect for loose components or signs of wear.
  • Ensure proper drainage is clear and functional.
  • Remove any dust and debris from surfaces and equipment.
  • Inspect for any blockages around motors and wiring.
  • Ensure that all tools and materials are stored properly.
  • Verify that ventilation is not obstructed.
  • Conduct a thorough visual inspection around the escalator.
  • Collect and dispose of any litter or foreign objects.
  • Check the area for any hazards that could affect safety.
  • Report any significant hazards to maintenance personnel.
  • Use a non-abrasive cleaner on panels and signage.
  • Wipe down surfaces with a microfiber cloth.
  • Check for any fading or damage to signs.
  • Ensure that all signage is securely attached.
  • Use a damp cloth to wipe down side panels.
  • Inspect for any damage or loose fittings.
  • Dry thoroughly to prevent water spots.
  • Ensure that all areas are free of dust and dirt.
  • Use a suitable lubricant to clean the chains.
  • Check for wear or damage to links.
  • Remove any buildup of dirt or debris.
  • Ensure that chains operate smoothly without obstruction.
  • Gently wipe sensors with a soft cloth.
  • Inspect for any signs of wear or misalignment.
  • Test functionality after cleaning to ensure accuracy.
  • Replace any faulty sensors as needed.
  • Remove any debris caught in the comb plates.
  • Wipe clean with a non-abrasive cloth.
  • Check for cracks or damage in the plates.
  • Ensure comb plates are securely attached.
  • Check all light fixtures for functionality.
  • Replace any burnt-out bulbs immediately.
  • Wipe fixtures with a damp cloth to remove dust.
  • Ensure that lighting is adequate and evenly distributed.
  • Identify and mark any hazardous areas.
  • Use absorbent materials to soak up spills.
  • Clean the area with appropriate cleaning agents.
  • Dispose of waste materials in accordance with regulations.
  • Review manufacturer’s guidelines for safe cleaning agents.
  • Test any new cleaning product on a small area first.
  • Avoid harsh chemicals that may damage surfaces.
  • Ensure proper ventilation when using cleaning agents.
  • Inspect all metal areas for rust or corrosion.
  • Use a rust remover or wire brush to clean affected areas.
  • Apply a protective coating if necessary.
  • Monitor regularly for any recurrence.
  • Review Material Safety Data Sheets (MSDS) for cleaning products.
  • Ensure all products are labeled and stored properly.
  • Dispose of cleaning materials in accordance with environmental regulations.
  • Train staff on proper handling and usage of cleaning agents.

6. Documentation

7. Final Inspection