A detailed Genset DAILY preventive maintenance Inspection checklist

1. Visual Inspection

2. Fluid Levels

3. Battery Condition

  • Look for any white or green corrosion on terminals.
  • Ensure terminal connections are snug and secure.
  • Use a wire brush to clean terminals if corrosion is found.
  • Set multimeter to the DC voltage setting.
  • Connect the red lead to the positive terminal and black lead to the negative terminal.
  • Record the voltage reading and compare with manufacturer's specifications.
  • Remove battery caps to check fluid levels.
  • Top off with distilled water if levels are low.
  • Ensure fluid is at the recommended level without overfilling.
  • Look for any white or green corrosion on terminals.
  • Ensure terminal connections are snug and secure.
  • Use a wire brush to clean terminals if corrosion is found.
  • Set multimeter to the DC voltage setting.
  • Connect the red lead to the positive terminal and black lead to the negative terminal.
  • Record the voltage reading and compare with manufacturer's specifications.
  • Remove battery caps to check fluid levels.
  • Top off with distilled water if levels are low.
  • Ensure fluid is at the recommended level without overfilling.

4. Electrical Connections

  • Use a torque wrench to check tightness.
  • Look for discoloration or burn marks.
  • Ensure all connections are securely fastened.
  • Examine insulation for cuts or abrasions.
  • Look for exposed copper or wires.
  • Replace any damaged wiring immediately.
  • Toggle each breaker to ensure functionality.
  • Inspect fuses for integrity and replacement need.
  • Document any tripped breakers or blown fuses.
  • Use a torque wrench to check tightness.
  • Look for discoloration or burn marks.
  • Ensure all connections are securely fastened.
  • Examine insulation for cuts or abrasions.
  • Look for exposed copper or wires.
  • Replace any damaged wiring immediately.
  • Toggle each breaker to ensure functionality.
  • Inspect fuses for integrity and replacement need.
  • Document any tripped breakers or blown fuses.
  • Use a wire brush to clean terminals.
  • Apply anti-corrosion spray if necessary.
  • Check for loose connections after cleaning.
  • Inspect grounding wires for physical damage.
  • Ensure grounding rods are properly installed.
  • Tighten any loose grounding connections.
  • Look for discoloration or bubbling of insulation.
  • Check for cracks that could expose wiring.
  • Replace any compromised insulation immediately.
  • Ensure wires are secured with proper clips.
  • Re-route wires if they are in danger of abrasion.
  • Inspect for potential pinch points.
  • Visually inspect each connector.
  • Gently tug on connectors to ensure they are secure.
  • Replace any connectors that do not lock properly.
  • Use a multimeter to check voltage levels.
  • Compare readings against manufacturer specifications.
  • Document any discrepancies for further investigation.
  • Check all control wire connections.
  • Look for signs of wear on insulation.
  • Secure any loose control wires found.
  • Cross-reference installed wiring with diagrams.
  • Ensure all modifications are documented.
  • Correct any discrepancies found during review.
  • Inspect terminals for corrosion buildup.
  • Tighten connections to prevent voltage drop.
  • Clean terminals with a mixture of baking soda and water.
  • Feel for heat on components and wires.
  • Look for discoloration or warping.
  • Replace any overheated components immediately.
  • Listen for clicking sounds during operation.
  • Inspect for physical wear or burning.
  • Replace any relays or contactors showing wear.
  • Record findings in a maintenance log.
  • Note any parts replaced or repaired.
  • Establish a follow-up schedule for ongoing issues.

5. Start-Up Test

  • Turn the ignition key to the 'ON' position.
  • Crank the genset engine.
  • Pay attention to any abnormal sounds such as grinding or rattling.
  • Immediately shut down if any unusual noise is detected.
  • Observe the control panel for warning indicators.
  • Check if any alarms are activated.
  • Take note of any alerts for further investigation.
  • Ensure all indicators return to normal after startup.
  • Observe the temperature gauge on the control panel.
  • Wait until the gauge indicates the normal operating range.
  • Allow time for the engine to warm up adequately.
  • Document the temperature reading in the maintenance log.
  • Inspect safety interlock systems visually.
  • Test each interlock switch to confirm it engages properly.
  • Ensure that all safety features are operational.
  • Do not start the genset if any interlock is faulty.
  • Locate the fuel supply valve.
  • Check that the valve is in the 'open' position.
  • Inspect for any blockages or leaks in the fuel line.
  • Correct any issues before proceeding to start.
  • Observe the oil pressure gauge as the genset starts.
  • Ensure that the pressure reading is within the normal range.
  • If the gauge indicates low pressure, shut down immediately.
  • Record the oil pressure reading for logs.
  • Monitor voltage and frequency displays closely.
  • Verify that readings are within specified limits.
  • Note any discrepancies for technical review.
  • Confirm stable readings before proceeding.
  • Stand close to the genset while it operates.
  • Identify any unusual vibrations or shaking.
  • If vibrations are excessive, shut down the genset.
  • Investigate the cause of any irregularities.
  • Let the genset idle for a minimum of 5 minutes.
  • Monitor performance during this period.
  • Listen for any abnormal sounds or behaviors.
  • Ensure stability before moving to the next step.
  • Check the ATS for proper functionality during startup.
  • Simulate a power outage if necessary.
  • Ensure the ATS switches over smoothly to generator power.
  • Record the operation status of the ATS.
  • Inspect the coolant level in the reservoir.
  • Ensure there are no leaks in the cooling system.
  • Check for proper flow in the cooling lines.
  • Verify that the radiator fan is operational.
  • Monitor power output readings consistently.
  • Check for any fluctuations in voltage or frequency.
  • Ensure stability before concluding the test.
  • Document any irregularities for follow-up.
  • Document all measurements taken during startup.
  • Include notes on any irregularities or concerns.
  • Ensure clarity and detail in the log entries.
  • Store the log in a designated maintenance file.

6. Load Testing

7. Exhaust System

  • Examine all joints and seams closely.
  • Use a leak detection solution if necessary.
  • Look for any signs of soot or discoloration.
  • Check for any audible hissing sounds.
  • Document any findings for repair.
  • Inspect for dents, rust, or corrosion.
  • Ensure there are no loose parts.
  • Listen for abnormal noises during operation.
  • Verify that it is securely mounted.
  • Check for proper drainage and venting.
  • Look for debris or foreign objects around the system.
  • Inspect the area for any signs of blockage.
  • Ensure that exhaust outlets are unobstructed.
  • Check for any signs of animal nests.
  • Clear any identified obstructions immediately.
  • Examine all joints and seams closely.
  • Use a leak detection solution if necessary.
  • Look for any signs of soot or discoloration.
  • Check for any audible hissing sounds.
  • Document any findings for repair.
  • Inspect for dents, rust, or corrosion.
  • Ensure there are no loose parts.
  • Listen for abnormal noises during operation.
  • Verify that it is securely mounted.
  • Check for proper drainage and venting.
  • Look for debris or foreign objects around the system.
  • Inspect the area for any signs of blockage.
  • Ensure that exhaust outlets are unobstructed.
  • Check for any signs of animal nests.
  • Clear any identified obstructions immediately.
  • Inspect all hangers for wear or damage.
  • Ensure that supports are adequately fastened.
  • Check for signs of rust on metal components.
  • Confirm that hangers are not sagging or broken.
  • Replace any damaged hangers promptly.
  • Look for discoloration or flaking paint.
  • Check all metallic parts for surface rust.
  • Use a wire brush to clean small areas.
  • Document any severe corrosion for repair.
  • Evaluate the need for protective coatings.
  • Listen for any irregular sounds during operation.
  • Feel for vibrations on the exhaust pipes.
  • Monitor for changes in noise levels.
  • Investigate the source of any unusual sounds.
  • Consult maintenance if issues persist.
  • Check that all pipes are correctly positioned.
  • Verify that connections are not under strain.
  • Adjust any misaligned components carefully.
  • Ensure there are no pinched or kinked sections.
  • Document alignment status for future reference.
  • Inspect gaskets for wear or damage.
  • Look for any signs of leaks around joints.
  • Ensure gaskets are properly seated.
  • Replace any faulty gaskets immediately.
  • Maintain a stock of replacement gaskets.
  • Use temperature gauges to check readings.
  • Compare readings to manufacturer specifications.
  • Look for any signs of overheating.
  • Investigate any abnormal temperature fluctuations.
  • Document temperature readings for records.
  • Check for cracks, dents, or rust.
  • Ensure it is securely attached.
  • Look for any signs of heat-related wear.
  • Replace it if it shows significant damage.
  • Document the condition for maintenance records.
  • Review local regulations regarding emissions.
  • Check for any required emissions testing.
  • Ensure all components meet compliance standards.
  • Document compliance status and any issues.
  • Stay updated on changing regulations.

8. Control Panel and Indicators

  • Inspect for any illuminated warning lights.
  • Check for displayed error codes.
  • Document any anomalies for follow-up.
  • Ensure control panel is free from dust and debris.
  • Start the generator and observe gauge readings.
  • Compare readings against normal operating ranges.
  • Note any discrepancies or malfunctions.
  • Report any issues immediately.
  • Test the emergency stop button functionality.
  • Confirm that the genset shuts down immediately.
  • Check for any warning indicators post-test.
  • Document the results of the test.
  • Inspect for any illuminated warning lights.
  • Check for displayed error codes.
  • Document any anomalies for follow-up.
  • Ensure control panel is free from dust and debris.
  • Start the generator and observe gauge readings.
  • Compare readings against normal operating ranges.
  • Note any discrepancies or malfunctions.
  • Report any issues immediately.
  • Test the emergency stop button functionality.
  • Confirm that the genset shuts down immediately.
  • Check for any warning indicators post-test.
  • Document the results of the test.
  • Toggle the main power switch on and off.
  • Observe any unusual sounds or resistance.
  • Ensure the switch returns to the 'on' position smoothly.
  • Report any irregularities.
  • Check each indicator light for illumination.
  • Replace any burnt-out bulbs as needed.
  • Ensure all indicators reflect accurate readings.
  • Document any failures.
  • Look for cracks, corrosion, or loose components.
  • Check for signs of overheating or burn marks.
  • Ensure all connections are secure.
  • Report any physical defects.
  • Press the start button and observe response.
  • Press the stop button to ensure proper shutdown.
  • Verify that both buttons are not sticky or jammed.
  • Document functionality results.
  • Review all programmable settings against standard configurations.
  • Make adjustments if any settings are incorrect.
  • Save and document all changes made.
  • Check for user permissions if applicable.
  • Activate alarms to test response.
  • Ensure alarms sound as expected.
  • Check that alarms reset without issues.
  • Document the alarm functionality.
  • Record the current runtime hours.
  • Compare with maintenance schedule requirements.
  • Document any significant changes.
  • Report discrepancies if any.
  • Check all communication ports for physical damage.
  • Ensure cables are securely connected.
  • Test connectivity with monitoring systems.
  • Report any connectivity issues.
  • Inspect labels for wear or fading.
  • Replace any illegible labels.
  • Verify that all markings are consistent with operation.
  • Document any replacements made.
  • Test battery backup functionality.
  • Measure battery voltage if possible.
  • Replace batteries that are not holding charge.
  • Document battery status.
  • Check for available updates from the manufacturer.
  • Install updates following manufacturer guidelines.
  • Document the version history.
  • Ensure stability post-update.

9. Safety and Emergency Equipment

10. Documentation

11. End of Day Procedures