A detailed Genset WEEKLY preventive maintenance checklist

1. Visual Inspection

2. Fluid Levels

  • Locate the dipstick and remove it.
  • Wipe clean and reinsert, then remove again.
  • Check oil level against the marked indicators.
  • Add oil through the filler cap if low.
  • Ensure not to overfill.
  • Ensure the engine is cool before opening.
  • Check the coolant level in the radiator.
  • Inspect the overflow tank level against the markings.
  • Top up with the appropriate coolant if low.
  • Look for leaks around hoses and connections.
  • Check the fuel gauge reading.
  • Open the fuel tank and visually inspect for clarity.
  • Look for water or sediment at the bottom.
  • Top up with clean fuel if necessary.
  • Seal the tank securely after inspection.
  • Locate the hydraulic fluid reservoir.
  • Check the fluid level against the dipstick or sight glass.
  • Add hydraulic fluid if below recommended levels.
  • Inspect for any leaks around hoses and seals.
  • Ensure the cap is securely closed after checking.
  • Identify the transmission fluid dipstick or access point.
  • Remove and clean the dipstick, then reinsert.
  • Check the fluid level against the markings.
  • Add appropriate transmission fluid if needed.
  • Inspect for discoloration or burnt smell.
  • Locate the power steering fluid reservoir.
  • Check the fluid level against the markings.
  • Add fluid if low using the correct type.
  • Inspect for leaks around hoses and connections.
  • Ensure the cap is securely fastened after checking.
  • Locate the brake fluid reservoir.
  • Check the fluid level against the minimum and maximum lines.
  • Add brake fluid if necessary, using the correct type.
  • Inspect for leaks around the brake lines.
  • Ensure the reservoir cap is secured after inspection.
  • Identify all grease points on the genset.
  • Check the grease levels at each point.
  • Use a grease gun to add lubricant as needed.
  • Wipe away excess grease to prevent buildup.
  • Ensure all fittings are properly sealed after greasing.
  • Locate the secondary fuel tank and access point.
  • Check the fuel gauge or visually inspect the tank.
  • Top up with clean fuel if levels are low.
  • Inspect for leaks or corrosion around the tank.
  • Seal the tank securely after inspection.
  • Remove the battery cover to access cells.
  • Check the electrolyte level in each cell.
  • Add distilled water if levels are below the plates.
  • Avoid overfilling to prevent spillage.
  • Replace the battery cover securely after checking.
  • Check the coolant mixture in the reservoir.
  • Ensure the correct ratio of antifreeze to water.
  • Add more antifreeze if needed for proper levels.
  • Inspect for leaks or corrosion in the cooling system.
  • Secure the reservoir cap after checking.
  • Identify specific lubricants required for the model.
  • Check levels against the manufacturer's recommendations.
  • Add lubricant if levels are low.
  • Inspect for leaks or any signs of wear.
  • Ensure all caps are securely closed after inspection.
  • Visually inspect all fluid reservoirs for leaks.
  • Check for discoloration or unusual odors in fluids.
  • Clean any spills and document findings.
  • Report any concerns to maintenance personnel.
  • Conduct repairs as necessary to prevent further issues.

3. Electrical System

  • Use a multimeter to measure voltage.
  • Compare readings to manufacturer's specifications.
  • Check for any signs of battery swelling or leakage.
  • Ensure terminals are clean and connections are tight.
  • Look for exposed wire or insulation damage.
  • Check for signs of overheating or burns.
  • Ensure no wires are pinched or chafing against surfaces.
  • Repair or replace damaged wiring as necessary.
  • Turn on the ignition and listen for motor engagement.
  • Observe the motor for smooth operation.
  • Check battery voltage during cranking.
  • Inspect starter connections for corrosion or looseness.
  • Visually inspect fuses for blown elements.
  • Use a multimeter to test continuity for each fuse.
  • Replace any blown fuses with the correct rating.
  • Document any fuse replacements or issues found.
  • Check that all indicators illuminate during startup.
  • Test each gauge for accurate readings under operation.
  • Inspect control buttons and switches for responsiveness.
  • Ensure all panel connections are secure.
  • Look for any signs of corrosion on terminals.
  • Tighten any loose connections securely.
  • Use a wire brush to clean corroded areas.
  • Apply dielectric grease to prevent future corrosion.
  • Check ground connections for corrosion or looseness.
  • Ensure grounding wire is intact and securely attached.
  • Test grounding with a multimeter for continuity.
  • Repair or replace any faulty grounding components.
  • Use a multimeter to measure output voltage.
  • Verify frequency with a frequency meter.
  • Compare readings to specified output parameters.
  • Address any discrepancies immediately.
  • Disconnect connectors and inspect for dirt or corrosion.
  • Clean connectors with electrical contact cleaner.
  • Ensure terminals are tight and free of moisture.
  • Reconnect ensuring a secure fit.
  • Activate emergency stop switch to ensure functionality.
  • Check that the generator shuts down immediately.
  • Inspect safety interlocks for proper engagement.
  • Document any failures or required repairs.
  • Inspect for physical signs of wear or burn marks.
  • Test relays for proper operation using a multimeter.
  • Ensure contactors engage smoothly without sticking.
  • Replace any faulty components as needed.
  • Look for cracks, fraying, or discoloration.
  • Check for any signs of moisture intrusion.
  • Ensure that insulation is intact and secure.
  • Replace damaged wires immediately.
  • Test voltage output under varying loads with a multimeter.
  • Check for any unusual fluctuations in voltage.
  • Inspect connections for tightness and corrosion.
  • Replace if readings are outside specifications.
  • Look for discoloration or burnt smells around components.
  • Feel for excessive heat on wires or connectors.
  • Ensure proper ventilation around electrical parts.
  • Address any overheating issues promptly.
  • Visually inspect all connections for tightness.
  • Check for moisture ingress or corrosion.
  • Dry any wet components and apply sealant if necessary.
  • Re-secure connections to prevent future issues.

4. System Functionality

  • Engage the starter and listen carefully.
  • Identify any grinding, rattling, or high-pitched sounds.
  • Note the duration and frequency of unusual noises.
  • Stop the generator if any alarming sounds occur.
  • Observe the temperature gauge immediately after startup.
  • Ensure the temperature remains within normal operating range.
  • Record the temperature readings at 5-minute intervals.
  • Look for rapid temperature increases that may indicate issues.
  • Inspect all indicator lights for abnormal signals.
  • Refer to the user manual for specific error codes.
  • Document any warnings or error codes displayed.
  • Resolve issues as per manufacturer recommendations.
  • Simulate a power outage to trigger the automatic start.
  • Verify the generator starts without manual intervention.
  • Once operational, simulate a return to utility power.
  • Ensure the generator stops automatically and note the response time.
  • Connect the generator to a designated load bank.
  • Run the generator at rated load for 15-30 minutes.
  • Monitor performance metrics such as voltage and frequency.
  • Check for any abnormal vibrations or noises during operation.
  • Set the multimeter to the appropriate voltage and frequency settings.
  • Measure the output voltage at the generator terminals.
  • Check the frequency to ensure it aligns with specifications.
  • Record measurements for future reference.
  • Inspect fuel lines and connections for signs of leaks.
  • Check fuel filters for blockages or damage.
  • Ensure that the fuel level is adequate for operation.
  • Listen for any unusual sounds from the fuel pump.
  • Examine exhaust pipes and joints for visible leaks.
  • Check for any unusual odors that may indicate exhaust issues.
  • Look for signs of rust or corrosion on the exhaust components.
  • Ensure that exhaust outlets are clear and unobstructed.
  • Inspect coolant levels and top off if necessary.
  • Check for leaks around hoses and connections.
  • Ensure fans are operating correctly during generator run.
  • Monitor coolant temperature to prevent overheating.
  • Test each gauge individually for responsiveness.
  • Compare readings against known benchmarks or specifications.
  • Look for erratic or non-functional gauges.
  • Document any discrepancies for review.
  • Check battery voltage with a multimeter.
  • Inspect battery terminals for corrosion or loose connections.
  • Test the charging system output while the generator is running.
  • Ensure the battery holds charge without issues.
  • Simulate conditions that would trigger a shutdown.
  • Observe the shutdown response of the generator.
  • Ensure all safety features activate correctly.
  • Document the functionality of each safety shutdown system.
  • Manually operate the transfer switch to check functionality.
  • Observe the switch for smooth operation without delays.
  • Ensure proper connections are secure and functional.
  • Test the switch under load conditions.
  • Test each button and switch for proper operation.
  • Ensure lights and displays are functioning correctly.
  • Check for any lag or non-responsiveness.
  • Document any issues for maintenance follow-up.
  • Create a detailed log of all observations.
  • Include timestamps and specific conditions during tests.
  • Highlight any areas needing attention or repair.
  • Review documentation with maintenance personnel.

5. Safety Checks

  • Inspect all guards for physical integrity.
  • Check mounting points and fasteners for tightness.
  • Ensure no gaps or misalignments are present.
  • Document any issues for immediate repair.
  • Activate the emergency stop button to verify functionality.
  • Listen for alarm sounds and check indicator lights.
  • Reset the system after testing and ensure normal operation.
  • Log results and any discrepancies.
  • Check the pressure gauge on each extinguisher.
  • Ensure extinguishers are installed in designated locations.
  • Inspect for signs of damage or corrosion.
  • Confirm inspection tags are up to date.
  • Inspect all safety signs for clarity and condition.
  • Replace any faded or damaged signs immediately.
  • Ensure signs are positioned for maximum visibility.
  • Document any replacements made.
  • Clear any debris or unnecessary materials.
  • Check for flammable substances stored nearby.
  • Identify and mitigate potential slip or trip hazards.
  • Record findings and corrective actions taken.
  • Verify that hard hats, gloves, and goggles are worn.
  • Ensure safety footwear is appropriate for the task.
  • Conduct a PPE compliance check before starting work.
  • Document any instances of non-compliance.
  • Assess airflow and ventilation systems in the area.
  • Ensure no obstructions are blocking air intake/outlet.
  • Check for exhaust leaks that may compromise safety.
  • Log ventilation conditions and any required improvements.
  • Inspect fans and vents for proper operation.
  • Check temperature readings to ensure systems are cooling effectively.
  • Listen for unusual noises indicating malfunction.
  • Document testing results and any maintenance needed.
  • Look for signs of fuel leakage or corrosion.
  • Check connections and fittings for tightness.
  • Ensure containment systems are functioning correctly.
  • Record findings and repair needs.
  • Inspect all exit routes for blockages.
  • Ensure that emergency exit signs are illuminated.
  • Check that doors open easily without obstructions.
  • Document exit condition and any issues found.
  • Inspect all wiring for signs of wear or fraying.
  • Check terminals and connections for tightness.
  • Look for signs of corrosion on electrical components.
  • Log any repairs or replacements needed.
  • Verify that SDS are current and accessible.
  • Ensure all staff are trained to read and understand SDS.
  • Update any outdated sheets with the latest information.
  • Document the review process and any changes made.
  • Schedule a meeting to discuss emergency procedures.
  • Provide training on evacuation routes and protocols.
  • Encourage questions and clarify roles during emergencies.
  • Document the training session and participant feedback.
  • Inspect first aid kits for completeness and expiration dates.
  • Ensure kits are easily accessible in case of emergency.
  • Review the location of kits with all team members.
  • Log findings and restock as necessary.
  • Check grounding connections for corrosion or damage.
  • Verify that grounding rods are properly installed.
  • Test grounding resistance to ensure effectiveness.
  • Document grounding condition and any necessary repairs.

6. Documentation

7. Cleanliness and Organization

  • Remove any loose debris from the genset and the area around it.
  • Use appropriate cleaning agents for spills and ensure complete removal.
  • Check for any oil or fuel spills and clean them using absorbent materials.
  • Gather all tools used during maintenance into a designated area.
  • Sort tools by type and size for easy access.
  • Store tools in labeled containers or toolboxes.
  • Collect all waste materials generated during maintenance.
  • Separate hazardous materials from non-hazardous waste.
  • Follow local regulations for disposal of each type of waste.
  • Locate service manuals and documentation in the storage area.
  • Ensure all materials are up-to-date and in good condition.
  • Organize documents in binders or folders for easy access.
  • Inspect each tool for signs of wear or damage.
  • Clean tools after use and ensure they are dry before storage.
  • Store tools in designated areas to prevent loss or damage.
  • Conduct a visual inspection of the genset housing.
  • Look for rust, cracks, or other signs of damage.
  • Report any issues and arrange for repairs as necessary.
  • Use a microfiber cloth to wipe surfaces gently.
  • Avoid abrasive materials that could scratch surfaces.
  • Ensure all areas, including vents and panels, are cleaned.
  • Inspect all labels for wear or fading.
  • Replace any illegible or damaged labels promptly.
  • Ensure that safety and operational labels are visible.
  • Check the location of fire extinguishers and first aid kits.
  • Ensure that extinguishers are charged and not expired.
  • Restock first aid kits with necessary supplies.
  • Identify a specific area for spare parts storage.
  • Organize parts by type and label storage containers.
  • Regularly review inventory and restock as needed.
  • Walk through storage areas to identify clutter or hazards.
  • Remove any items that do not belong in the storage area.
  • Report any safety hazards immediately.
  • Use clear and durable labels on all containers.
  • Include contents and any necessary safety information.
  • Ensure labels are visible and easy to read.
  • Create a weekly cleaning checklist for maintenance personnel.
  • Assign specific tasks to individuals or teams.
  • Review and adjust the schedule as needed.
  • Inspect cords and hoses for damage or wear.
  • Coil cords and hoses neatly and use ties to secure them.
  • Ensure that all connections are secure and not a tripping hazard.
  • Schedule periodic reviews of cleanliness protocols.
  • Gather feedback from maintenance personnel on current practices.
  • Update protocols based on lessons learned and best practices.

8. Review and Planning