A detailed Water Cooled Compression Chiller QUARTERLY preventive maintenance checklist

1. Safety Precautions

  • Inspect PPE for damage or wear before use.
  • Provide safety goggles, gloves, and hearing protection as needed.
  • Ensure respirators are available if required for the task.
  • Train personnel on proper PPE usage and limitations.
  • Identify all energy sources connected to the chiller.
  • Use lockout devices on all energy isolating switches.
  • Tagout with clear identification of work being performed.
  • Verify isolation by attempting to start the chiller.
  • Remove any unnecessary tools or materials from the area.
  • Check for slip, trip, and fall hazards.
  • Ensure sufficient airflow and check for fumes or gases.
  • Use fans or ventilation systems if necessary.

2. Visual Inspection

  • Look for dents, scratches, or cracks.
  • Check for rust or corrosion.
  • Ensure seals and gaskets are intact.
  • Inspect for any paint peeling or flaking.
  • Look for wet spots or puddles.
  • Inspect joints and connections closely.
  • Use a leak detection solution if necessary.
  • Ensure all fittings are tight and secure.
  • Check for visible tears or cracks.
  • Ensure insulation is securely attached.
  • Look for signs of moisture or mold.
  • Inspect for any exposed refrigerant lines.
  • Remove any visible debris or buildup.
  • Check for rust or corrosion in the basin.
  • Ensure proper water levels are maintained.
  • Inspect the basin for leaks or cracks.
  • Look for any exposed wires or insulation.
  • Check for signs of overheating or burn marks.
  • Ensure connections are tight and secure.
  • Inspect for corrosion on terminals and connectors.
  • Inspect for cracks or breaks in isolators.
  • Ensure mounts are securely fastened.
  • Check for signs of excessive vibration.
  • Replace any damaged isolators or mounts.
  • Check for dirt buildup on fan blades.
  • Inspect coils for bent fins or debris.
  • Ensure fans rotate freely without obstruction.
  • Clean with appropriate tools if necessary.
  • Look for visible leaks around the valve.
  • Check for rust or corrosion on components.
  • Ensure the valve operates smoothly.
  • Inspect connections for tightness.
  • Ensure sight glass is free of obstructions.
  • Check for bubbles indicating low refrigerant.
  • Confirm visibility of refrigerant levels.
  • Inspect for any leaks around the sight glass.
  • Look for water accumulation around the pump.
  • Check for rust or corrosion on the pump body.
  • Listen for unusual noises during operation.
  • Inspect seals for integrity.
  • Check for discoloration or burns on the line.
  • Inspect for insulation damage.
  • Ensure there are no obstructions.
  • Feel for excessive heat during operation.
  • Inspect for any warning lights or alarms.
  • Check for physical damage to the panel.
  • Ensure all buttons and switches function properly.
  • Look for loose connections inside the panel.
  • Check for visible blockages in the drain.
  • Ensure water flows freely through the lines.
  • Look for any signs of leaks or corrosion.
  • Clear any debris or buildup as needed.
  • Check that panels close and latch properly.
  • Inspect for signs of wear or damage.
  • Ensure all screws and fasteners are tight.
  • Look for any gaps that may allow debris entry.

3. Electrical System Check

  • Use a torque wrench to ensure connections are tight.
  • Look for any signs of corrosion or discoloration.
  • Clean connections with a suitable electrical cleaner.
  • Apply anti-corrosion compound where necessary.
  • Power on the control panel and access the display.
  • Record any error codes or alarms present.
  • Refer to the manual for troubleshooting steps.
  • Reset the system if no issues are found.
  • Activate each safety device individually.
  • Confirm that alarms and indicators respond correctly.
  • Inspect physical condition and mounting of devices.
  • Document any failures or required replacements.
  • Listen for audible clicks when engaging contactors.
  • Check for overheating or burn marks.
  • Test relays with a multimeter for continuity.
  • Replace any faulty components immediately.
  • Examine insulation for cracks or abrasions.
  • Look for exposed wiring or loose connections.
  • Replace any damaged or worn wiring.
  • Secure loose wires to prevent movement.
  • Use a clamp meter to measure current draw.
  • Check voltage at the terminals with a multimeter.
  • Compare readings to manufacturer specifications.
  • Document any discrepancies for further analysis.
  • Switch off power and visually inspect breakers and fuses.
  • Reset each circuit breaker and check for proper operation.
  • Replace any blown fuses with the correct rating.
  • Document any replacements made.
  • Inspect all grounding connections for tightness.
  • Use a multimeter to test continuity to ground.
  • Ensure grounding meets local electrical codes.
  • Replace any corroded or damaged grounding components.
  • Adjust the thermostat to test its response.
  • Use a calibrated measuring device to check accuracy.
  • Clean any dust or debris from the thermostat.
  • Document any calibration adjustments made.
  • Monitor power supply voltage using a recording meter.
  • Look for signs of voltage spikes or drops.
  • Check connections to the power source for stability.
  • Report any irregularities to electrical personnel.
  • Use a power factor meter to measure the power factor.
  • Record the reading and compare to acceptable ranges.
  • Investigate low power factor causes and solutions.
  • Document findings for future reference.
  • Inspect timers for proper operation and settings.
  • Check sensors for accuracy and responsiveness.
  • Clean any debris or obstructions affecting sensors.
  • Replace malfunctioning components as needed.
  • Test each emergency shut-off switch for responsiveness.
  • Ensure clear labeling and accessibility of switches.
  • Check for mechanical integrity and proper mounting.
  • Document any issues found during testing.
  • Gather all documentation of previous electrical work.
  • Update schematics to reflect any modifications.
  • Ensure all changes comply with industry standards.
  • Store updated schematics in an accessible location.

4. Refrigerant System Evaluation

  • Use electronic leak detectors or soap bubbles.
  • Check all joints, fittings, and connections.
  • Record any detected leaks for further action.
  • Ensure safety protocols are followed during inspection.
  • Check for smooth operation of the valve.
  • Listen for any unusual sounds during operation.
  • Confirm that solenoid valves open and close correctly.
  • Inspect electrical connections for signs of wear.
  • Use appropriate gauges to measure temperatures.
  • Calculate superheat and subcooling values.
  • Compare measurements with manufacturer specifications.
  • Adjust system settings if necessary.
  • Remove any debris or obstructions from coils.
  • Use a soft brush or vacuum for cleaning.
  • Check for signs of corrosion or damage.
  • Ensure fans are operational and providing adequate airflow.
  • Examine insulation for tears or degradation.
  • Replace any damaged insulation immediately.
  • Clean lines to prevent contamination.
  • Ensure proper support and alignment of refrigerant lines.
  • Connect pressure gauges to appropriate service ports.
  • Record pressure readings accurately.
  • Compare readings with manufacturer guidelines.
  • Identify and address any discrepancies.
  • Use a digital hygrometer and thermometer.
  • Record data in a maintenance log.
  • Analyze how ambient conditions affect system efficiency.
  • Adjust system operation as needed.
  • Activate the recovery system and observe operation.
  • Check for proper suction and discharge pressures.
  • Inspect hoses and connections for leaks.
  • Document the condition and performance.
  • Test each safety control for functionality.
  • Check pressure switch settings against specifications.
  • Ensure reset functions are operational.
  • Replace any faulty components immediately.
  • Listen for abnormal sounds during operation.
  • Use a vibration meter to assess performance.
  • Inspect mounting and alignment of the compressor.
  • Document any irregularities for further investigation.
  • Check the system nameplate for specifications.
  • Ensure correct refrigerant type is used.
  • Record the refrigerant charge in maintenance logs.
  • Verify compliance with environmental regulations.
  • Inspect sight glasses for clarity and bubbles.
  • Check moisture indicators for color change.
  • Replace any defective components immediately.
  • Ensure proper sealing after replacement.
  • Check for signs of clogging or saturation.
  • Test pressure drop across the filter drier.
  • Replace if performance is below specifications.
  • Document replacement in maintenance logs.
  • Maintain a detailed maintenance log.
  • Record dates, types of refrigerant, and quantities.
  • Include notes on system modifications.
  • Ensure logs are accessible for future inspections.

5. Water System Maintenance

  • Shut down the chiller and isolate the water system.
  • Connect a hose to the drain valve and direct water to a safe location.
  • Open the fill valve to introduce fresh water while draining.
  • Continue until water runs clear, indicating sediment removal.
  • Reopen the system and check for leaks before restarting.
  • Shut down the cooling tower and disconnect power.
  • Remove debris from the tower basin and around the fill media.
  • Inspect fill media for scaling or blockage; clean as necessary.
  • Check nozzles for clogs and clean using appropriate tools.
  • Reassemble parts and ensure proper operation before restarting.
  • Review chemical feed rates and adjust as per manufacturer guidelines.
  • Test water samples for pH, alkalinity, and other parameters.
  • Inspect chemical dosing equipment for leaks or malfunctions.
  • Replace any expired or depleted chemical supplies.
  • Document findings and adjustments for future reference.
  • Listen for unusual sounds while the pump is operating.
  • Check for vibrations indicating misalignment or wear.
  • Inspect the pump motor and bearings for any signs of damage.
  • Ensure proper lubrication of moving parts as needed.
  • Document any issues for further investigation or repair.
  • Locate strainers or filters in the water system.
  • Shut down the system and relieve pressure before removal.
  • Clean or replace strainers/filters based on condition.
  • Check gaskets and seals for wear and replace if necessary.
  • Reinstall components securely and restart the system.
  • Measure current flow rates using flow meters.
  • Compare readings with specifications for optimal operation.
  • Adjust valves or pumps to achieve desired flow rates.
  • Monitor system for stability after adjustments.
  • Document flow rate changes and any observations.
  • Visually inspect all piping for signs of leaks or corrosion.
  • Check joints and connections for any signs of wear.
  • Use appropriate tools to test for hidden leaks.
  • Replace or repair damaged sections as needed.
  • Ensure all repairs meet safety and performance standards.
  • Check insulation for tears, gaps, or signs of moisture.
  • Ensure insulation is intact and properly secured.
  • Replace or repair any damaged insulation promptly.
  • Monitor for temperature fluctuations indicating insulation failure.
  • Document insulation condition and any actions taken.
  • Use calibrated instruments to test sensor accuracy.
  • Compare readings against known temperature standards.
  • Adjust or recalibrate sensors as needed for accuracy.
  • Document calibration results and any adjustments made.
  • Schedule regular testing intervals for ongoing accuracy.
  • Inspect heat exchangers for signs of fouling or scaling.
  • Use appropriate cleaning solutions to remove buildup.
  • Check for leaks or damage during inspection.
  • Document findings and schedule any necessary repairs.
  • Monitor performance post-cleaning to ensure efficiency.
  • Manually operate each valve to ensure smooth function.
  • Check for leaks or stiffness in valve operation.
  • Adjust valve positions to ensure proper flow control.
  • Replace damaged valves as necessary.
  • Document valve condition and adjustments made.
  • Analyze recent water quality test results.
  • Adjust treatment protocols to meet any changes in water quality.
  • Ensure compliance with local regulations and manufacturer guidelines.
  • Document updates to the treatment program.
  • Schedule follow-up tests to monitor effectiveness.
  • Check air charge level using a pressure gauge.
  • Inspect for leaks around fittings and connections.
  • Adjust air charge as necessary to manufacturer specifications.
  • Ensure tank is securely mounted and free from damage.
  • Document condition and any service performed.
  • Test all safety devices including pressure relief valves.
  • Check alarms and sensors for proper functioning.
  • Ensure compliance with local regulations and safety standards.
  • Document findings and any corrective actions taken.
  • Schedule regular inspections to maintain compliance.

6. Performance Testing

  • Use calibrated gauges to check pressure at the inlet and outlet.
  • Record temperature readings from sensors at key points.
  • Ensure readings are taken under stable operating conditions.
  • Document results in the maintenance log for reference.
  • Calculate the coefficient of performance (COP) based on input and output data.
  • Review energy consumption against cooling output.
  • Identify any deviations from expected efficiency benchmarks.
  • Summarize findings for management review.
  • Measure inlet and outlet temperatures for both condenser and evaporator.
  • Calculate the temperature differential (TD) for both units.
  • Ensure TD is within manufacturer recommended ranges.
  • Report any significant discrepancies for further investigation.
  • Gather manufacturer performance specifications for comparison.
  • Analyze recorded data against these specifications.
  • Identify any areas of underperformance.
  • Prepare a report highlighting discrepancies.
  • Use calibrated gauges to check pressure at the inlet and outlet.
  • Record temperature readings from sensors at key points.
  • Ensure readings are taken under stable operating conditions.
  • Document results in the maintenance log for reference.
  • Calculate the coefficient of performance (COP) based on input and output data.
  • Review energy consumption against cooling output.
  • Identify any deviations from expected efficiency benchmarks.
  • Summarize findings for management review.
  • Measure inlet and outlet temperatures for both condenser and evaporator.
  • Calculate the temperature differential (TD) for both units.
  • Ensure TD is within manufacturer recommended ranges.
  • Report any significant discrepancies for further investigation.
  • Gather manufacturer performance specifications for comparison.
  • Analyze recorded data against these specifications.
  • Identify any areas of underperformance.
  • Prepare a report highlighting discrepancies.
  • Monitor electrical usage with a power meter.
  • Record kilowatt usage during peak and normal operations.
  • Compare findings against expected consumption levels.
  • Report any anomalies for troubleshooting.
  • Check drive settings and operational parameters.
  • Monitor any fluctuations in speed and torque.
  • Assess how drive adjustments impact overall chiller efficiency.
  • Document findings and recommend adjustments if needed.
  • Use a hygrometer to measure ambient humidity.
  • Record outdoor temperature using a reliable thermometer.
  • Analyze how these conditions affect chiller performance.
  • Keep records for future reference.
  • Inspect cooling tower for buildup or blockages.
  • Measure water temperature entering and leaving the tower.
  • Evaluate airflow and fan operation.
  • Document any maintenance needs.
  • Listen for abnormal noises during chiller operation.
  • Use vibration analysis tools to assess operating condition.
  • Identify and record any concerning vibrations.
  • Investigate causes and plan for repairs if needed.
  • Measure flow rates using flow meters at key points.
  • Compare readings with specifications from the manufacturer.
  • Identify any issues with flow that may affect performance.
  • Document and address any discrepancies.
  • Test all safety controls for proper functionality.
  • Simulate alarm conditions to ensure alarms activate.
  • Document the results of safety checks.
  • Implement corrective actions for any failures.
  • Record any performance discrepancies in detail.
  • Analyze potential causes for performance issues.
  • Suggest viable corrective actions to management.
  • Follow up on implemented solutions.
  • Increase load gradually to the chiller's rated capacity.
  • Monitor temperature and pressure during the test.
  • Ensure stability and efficiency under load conditions.
  • Record results for compliance and future reference.
  • Inspect pumps and fans for proper operation.
  • Check for any leaks, unusual noises, or vibrations.
  • Ensure ancillary systems are functioning within specifications.
  • Document any issues and schedule necessary repairs.

7. Documentation and Reporting

8. Final Inspection

  • Check all toolboxes and storage areas.
  • Verify that equipment used during maintenance is accounted for.
  • Remove any temporary setups or scaffolding.
  • Ensure the work area is clean and tidy.
  • Confirm all maintenance work is complete.
  • Remove lockout devices in the correct sequence.
  • Restore power according to safety protocols.
  • Notify all personnel that power is being restored.
  • Inspect all panels and components for proper installation.
  • Check that all tools and equipment are removed.
  • Look for any visible signs of leaks or issues.
  • Ensure all safety guards are in place.
  • Gather team members in a designated area.
  • Discuss any maintenance challenges faced.
  • Share solutions implemented during maintenance.
  • Encourage questions and feedback from team members.
  • Inspect each panel for proper alignment.
  • Ensure screws and fasteners are tightened.
  • Check for any missing covers or panels.
  • Confirm that seals are intact.
  • Inspect all piping and connection points.
  • Look for discoloration or moisture accumulation.
  • Use a leak detection solution if necessary.
  • Document any leaks found for further action.
  • Check that guards are not damaged or loose.
  • Confirm that shields cover all moving parts.
  • Test guards for accessibility and ease of use.
  • Ensure that all safety features are operational.
  • Activate each emergency shut-off switch.
  • Observe the immediate response of the chiller.
  • Check for any error codes or alarms.
  • Ensure accessibility of shut-off switches is clear.
  • Ensure all entries reflect recent maintenance actions.
  • Correct any discrepancies found during the review.
  • Include dates and details of completed tasks.
  • Store logs in an accessible location.
  • Check temperature, pressure, and fluid levels.
  • Compare readings to manufacturer guidelines.
  • Adjust settings as needed to meet specifications.
  • Document any adjustments made.
  • Clear any obstructions around the chiller.
  • Look for any loose materials or tools left behind.
  • Check for spills or hazardous materials.
  • Ensure proper drainage around the unit.
  • Check that all signs are in good condition.
  • Replace any faded or damaged signage.
  • Ensure signs are positioned for maximum visibility.
  • Confirm that instructions are clear and easy to read.
  • Inspect valves for proper function and positioning.
  • Open and close valves to test operation.
  • Check for leaks around valve connections.
  • Confirm that valves are labeled correctly.
  • Record all findings from the final inspection.
  • Include suggestions for future maintenance needs.
  • Note any recurring issues for follow-up.
  • Share the report with relevant stakeholders.