A detailed WATER Cooled Transformer DAILY preventive maintenance checklists

Visual Inspection

Cooling System Check

  • Locate the water level gauge.
  • Ensure the level is between minimum and maximum indicators.
  • If low, add water to reach acceptable levels.
  • Document any discrepancies in maintenance logs.
  • Examine inlets and outlets visually for debris.
  • Check for any signs of leaks around connections.
  • Clear blockages if present using appropriate tools.
  • Report any leaks to maintenance for immediate repair.
  • Activate cooling pumps and listen for normal sounds.
  • Look for vibrations or irregular noises that indicate issues.
  • Inspect pump housing for leaks or corrosion.
  • Document observations and schedule repairs if needed.
  • Use a thermometer to measure water temperature.
  • Compare readings with specified temperature limits.
  • Adjust cooling settings if temperature is outside range.
  • Report any temperature regulation issues immediately.
  • Examine all visible piping for corrosion or rust.
  • Look for cracks, leaks, or signs of deterioration.
  • Ensure that all joints and fittings are secure.
  • Document any findings for further action.
  • Check the manual settings against the specified temperature.
  • Observe valve movement during operation.
  • Listen for unusual sounds indicating malfunctions.
  • Record the performance and any discrepancies noted.
  • Manually activate flow switches to test response.
  • Verify that flow indicators show expected readings.
  • Inspect wiring for signs of wear or damage.
  • Note any irregularities for follow-up.
  • Look for deposits on the heat exchanger surfaces.
  • Check for any signs of leaks or inefficiencies.
  • Assess cleanliness and flow capacity.
  • Schedule cleaning if fouling is significant.
  • Check bleed valves for accessibility and functionality.
  • Release trapped air while monitoring pressure gauges.
  • Ensure fluid flows freely after bleeding.
  • Document the bleeding process and results.
  • Test each alarm for audible and visual alerts.
  • Verify alarm settings against operational requirements.
  • Check for any error messages on control panels.
  • Update alarm configurations as needed.
  • Use a thermometer to measure ambient temperature.
  • Note any significant fluctuations from normal ranges.
  • Investigate potential causes of temperature changes.
  • Report findings to maintenance personnel.
  • Inspect insulation for damage or wear.
  • Ensure all pipes are adequately covered.
  • Look for gaps or areas needing repair.
  • Schedule insulation replacement if necessary.
  • Examine logs for documented concerns.
  • Identify patterns or recurring issues.
  • Discuss findings with maintenance team.
  • Plan for preventive measures based on history.
  • Check all connections for tightness and security.
  • Look for discoloration or melting at connection points.
  • Ensure that wires are insulated and free from damage.
  • Document any issues for immediate attention.

Electrical Connections

  • Examine connections visually for discoloration or melting.
  • Use a temperature probe to check for hotspots.
  • Look for any signs of oxidation or rust.
  • Document findings for further action if necessary.
  • Use a torque wrench to tighten connections to specified values.
  • Check each terminal for movement or play.
  • Reassess torque levels periodically to ensure stability.
  • Record the maintenance performed for future reference.
  • Inspect wiring routes for sagging or tension.
  • Look for frayed wires or exposed conductors.
  • Gently tug each wire to check for secure attachment.
  • Replace any damaged insulation immediately.
  • Inspect grounding wires for corrosion or damage.
  • Use a multimeter to test continuity of grounding connections.
  • Ensure grounding connections are securely fastened.
  • Confirm that grounding points meet safety standards.
  • Examine fuses for discoloration or blown elements.
  • Check circuit breakers for tripping or physical damage.
  • Test the operation of each breaker manually.
  • Replace any defective fuses or breakers promptly.
  • Conduct functional tests on each relay.
  • Verify settings against operational requirements.
  • Check for any indicator lights or alarms.
  • Document the test results for future reference.
  • Calibrate the micro-ohmmeter before testing.
  • Measure resistance at each connection point.
  • Record resistance values for comparison.
  • Identify and address any high-resistance issues.
  • Consult manufacturer documents for specific torque values.
  • Use a calibrated torque wrench for accuracy.
  • Recheck torque after any maintenance work.
  • Log torque values for documentation.
  • Inspect connections for burn marks or soot.
  • Listen for unusual sounds during operation.
  • Monitor connections during load testing.
  • Document any findings for corrective action.
  • Inspect gaskets and seals for wear.
  • Check for signs of moisture inside enclosures.
  • Use a moisture meter if necessary.
  • Replace any compromised seals immediately.
  • Check for loose fittings or supports.
  • Ensure trays are not overloaded or sagging.
  • Clear any debris or obstructions from trays.
  • Document any necessary repairs or adjustments.
  • Look for cuts, nicks, or frayed insulation.
  • Check cable routing for pinch points.
  • Examine connections for secure attachment.
  • Replace damaged cables as needed.
  • Use a standardized form for documentation.
  • Include details such as location and type of defect.
  • Prioritize issues based on severity.
  • Schedule follow-up actions promptly.
  • Verify that circuit diagrams are up to date.
  • Cross-check wiring against the actual configuration.
  • Identify any discrepancies and correct them.
  • Ensure documentation reflects any changes made.

Control and Monitoring Systems

  • Check each instrument for operational indicators.
  • Trigger alarms to verify sound and visual alerts.
  • Ensure all readings are accurate and within acceptable ranges.
  • Record any non-functional instruments for repair.
  • Access and analyze logs from the monitoring system.
  • Identify abnormal entries or persistent alarms.
  • Document findings and escalate any critical issues.
  • Ensure logs are archived according to protocols.
  • Use a soft cloth or vacuum to remove dust.
  • Inspect for any obstructions around the panels.
  • Check that all labels are legible and intact.
  • Wipe down surfaces with appropriate cleaning agents.
  • Test all communication devices for connectivity.
  • Verify that data transmission is accurate and timely.
  • Inspect for any loose connections or damaged cables.
  • Document any issues for follow-up.
  • Use calibration tools to check each instrument.
  • Adjust settings as necessary to meet specifications.
  • Document calibration results and any adjustments made.
  • Schedule recalibration if instruments are out of spec.
  • Log into the remote monitoring interface.
  • Verify that data is being received and displayed correctly.
  • Test alert systems for remote notifications.
  • Document any connectivity issues encountered.
  • Simulate a power failure to activate backup systems.
  • Check if all systems seamlessly switch to backup power.
  • Test the duration of backup power supply.
  • Document performance and any issues encountered.
  • Check for available updates from the manufacturer.
  • Backup existing software before making changes.
  • Install updates and verify proper functionality post-update.
  • Document all changes made during the update process.
  • Look for frayed wires or loose connections.
  • Check for signs of overheating or corrosion.
  • Ensure all connections are secure and properly insulated.
  • Document any repairs or replacements needed.
  • Test each interlock mechanism for proper operation.
  • Simulate emergency conditions to check shutdown response.
  • Ensure all systems reset properly after tests.
  • Document the results and any issues identified.
  • Create a report summarizing any irregularities.
  • Include timestamps and specific instruments affected.
  • Escalate critical issues to the maintenance team.
  • Maintain records for future reference.
  • Create fault conditions to test alarm response.
  • Monitor and ensure alarms activate as expected.
  • Evaluate response time and accuracy of alerts.
  • Document the testing process and outcomes.
  • Verify data exchange between systems is functioning.
  • Test control commands from one system to another.
  • Check for any communication errors or delays.
  • Document integration status and any discrepancies.
  • Test backup systems to ensure they activate correctly.
  • Verify that redundancy protocols are in place.
  • Check for alerts on primary system failure.
  • Document test results and any issues found.

Fluid Levels and Quality

  • Locate the oil level gauge on the transformer.
  • Ensure oil is at the recommended level.
  • If low, use appropriate oil type to top up.
  • Avoid overfilling to prevent spills.
  • Seal the oil cap securely after topping up.
  • Visually assess oil color and clarity.
  • Look for cloudiness, particles, or discoloration.
  • Check for any separation of substances.
  • Use a clean container for sampling if needed.
  • Report any contamination to maintenance personnel.
  • Collect water sample from cooling system.
  • Use pH meter to measure acidity/alkalinity.
  • Test conductivity with appropriate meter.
  • Compare results against specification benchmarks.
  • Document readings for future reference.
  • Inspect seals and connections visually.
  • Look for oil stains or puddles.
  • Check tightness of all fittings.
  • Use a cloth to wipe areas for better visibility.
  • Report any leaks immediately for repair.
  • Use a calibrated thermometer for accurate readings.
  • Check against manufacturer's specified temperature range.
  • Document temperatures for both oil and water.
  • Investigate any deviations beyond operational limits.
  • Open the inspection port carefully.
  • Use a flashlight to illuminate the tank bottom.
  • Look for visible particulates or sediment accumulation.
  • Report any findings and consider filtration if needed.
  • Collect a sample of the oil using a clean method.
  • Send the sample to a laboratory for analysis.
  • Review the results for any alarming gas levels.
  • Take action based on lab recommendations.
  • Use proper safety equipment while inspecting.
  • Take note of any strong or unusual smells.
  • Investigate the source of the odor.
  • Consider oil testing if odors are detected.
  • Visually inspect all joints and connections.
  • Look for signs of rust, corrosion, or water stains.
  • Check for any unusual moisture around the unit.
  • Report and address any leaks immediately.
  • Remove filters and strainers carefully.
  • Check for any blockages or build-up.
  • Clean or replace components as per schedule.
  • Ensure replacements meet specifications.
  • Use a standardized log format for consistency.
  • Include date, time, and technician's name.
  • Attach any lab analysis results if applicable.
  • Store records in a secure location for future audits.
  • Inspect all filtration system components.
  • Check for proper flow rates and pressure.
  • Clear any detected obstructions immediately.
  • Test functionality after any maintenance is performed.
  • Review technical data sheets for both fluids.
  • Consult with manufacturers if compatibility is unclear.
  • Perform a compatibility test if necessary.
  • Document and address any compatibility issues found.
  • Review oil test results against standards.
  • Determine if oil meets operational criteria.
  • Plan for replacement or treatment if required.
  • Notify management of any significant changes needed.