Air cooled compression chiller quarterly, semi annual, annual preventive maintenance checklists

Quarterly Preventive Maintenance Checklist

  • Turn off the chiller and disconnect power.
  • Remove any debris and dirt from the coils using a soft brush or vacuum.
  • If necessary, use a coil cleaner and rinse thoroughly with water.
  • Check for any signs of damage or corrosion.
  • Use a pressure gauge to measure refrigerant levels.
  • Inspect all joints, connections, and components for signs of leaks.
  • Apply leak detection solution to suspect areas.
  • Record any findings and address leaks immediately.
  • Test all safety control devices according to manufacturer specifications.
  • Check for any error codes or alarms on the control panel.
  • Simulate fault conditions to ensure safety systems respond appropriately.
  • Document the results of the tests.
  • Power down the unit and use insulated tools.
  • Check all terminal connections for tightness.
  • Look for signs of corrosion or wear on wires.
  • Clean any corroded connections and replace damaged wires.
  • Remove the air filters from their housing.
  • Inspect for dirt, damage, or clogging.
  • Clean reusable filters with water or replace as necessary.
  • Reinstall filters securely in the correct orientation.
  • Turn on the chiller and observe fan operation.
  • Listen for any abnormal sounds indicating issues.
  • Inspect fan blades for damage or obstructions.
  • Lubricate bearings if applicable.
  • Check drain pans for standing water or debris.
  • Clear any blockages in drain lines.
  • Ensure proper slope for adequate drainage.
  • Inspect for rust or damage to drain pans.
  • Use a calibrated thermometer to check ambient temperatures.
  • Adjust thermostat settings as per manufacturer guidelines.
  • Verify responsiveness to temperature changes.
  • Document calibration adjustments made.
  • Turn off the chiller and disconnect power.
  • Remove debris using a soft brush or vacuum.
  • Use a suitable coil cleaner and rinse if necessary.
  • Inspect for any damage or corrosion.
  • Identify lubrication points on fan motors and bearings.
  • Use the manufacturer-recommended lubricant.
  • Avoid over-lubrication to prevent damage.
  • Wipe away excess lubricant after application.
  • Inspect insulation for signs of wear, tears, or moisture.
  • Replace damaged insulation to prevent energy loss.
  • Ensure insulation fits snugly around refrigerant lines.
  • Check for any gaps or loose areas.
  • Examine the compressor casing for cracks or leaks.
  • Listen for unusual noises during operation.
  • Check for signs of overheating or vibration.
  • Document any findings and schedule repairs if needed.
  • Verify all control system functions against specifications.
  • Check for accurate readings on gauges and displays.
  • Simulate control inputs to observe chiller response.
  • Document any irregularities or necessary adjustments.
  • Gather all previous service records and logs.
  • Update records with current maintenance actions taken.
  • Ensure all entries are accurate and complete.
  • File documents securely for future reference.
  • Ensure no obstructions are present around the unit.
  • Measure airflow with an anemometer if necessary.
  • Check intake and exhaust areas for debris.
  • Maintain adequate clearance as per manufacturer guidelines.
  • Remove dust, dirt, and debris from the chiller surface.
  • Inspect for any signs of damage or corrosion.
  • Ensure vents and air intakes are clear.
  • Document any issues found during inspection.
  • Check for any signs of frost or ice buildup.
  • Measure temperature and pressure at the valve.
  • Inspect for leaks or damage to the valve.
  • Ensure proper adjustment and functionality.
  • Monitor chiller operating parameters against specifications.
  • Evaluate energy consumption and compare with benchmarks.
  • Identify any performance issues or inefficiencies.
  • Document findings and recommendations for improvements.
  • Check mounts for wear or damage.
  • Ensure all mounts are properly secured.
  • Examine support structures for stability.
  • Replace or repair as needed to reduce vibration.
  • Inspect all safety guards for proper installation.
  • Check access panels for tight closures.
  • Ensure no missing or damaged safety components.
  • Document any issues and take corrective action.
  • Measure water flow rates using appropriate gauges.
  • Adjust valves to achieve specified flow rates.
  • Check pressure settings against manufacturer recommendations.
  • Document adjustments made during the inspection.
  • Simulate alarm conditions to test functionality.
  • Verify sound and visual alerts operate correctly.
  • Document any issues with alarms.
  • Ensure all alarms are reset after testing.
  • Check pump operation for unusual noises or vibrations.
  • Inspect piping for leaks or damage.
  • Ensure proper flow through the system.
  • Document any findings and necessary repairs.
  • Gather notes from previous inspections.
  • Prioritize outstanding issues based on urgency.
  • Schedule necessary repairs or follow-up actions.
  • Document actions taken to resolve outstanding issues.

Semi-Annual Preventive Maintenance Checklist

  • Review quarterly checklist and ensure all tasks are completed.
  • Document any issues found during quarterly maintenance.
  • Ensure all logs are updated to reflect completed tasks.
  • Use the appropriate tools to check tightness of connections.
  • Inspect for any signs of wear or corrosion.
  • Re-torque connections according to manufacturer specifications.
  • Remove any debris or buildup from the coils.
  • Use a soft brush or vacuum to clean the surfaces.
  • Ensure coils are dry before reassembling any components.
  • Use the recommended lubricant for the specific motor.
  • Apply lubricant to all appropriate points as per guidelines.
  • Check for any unusual noises indicating bearing issues.
  • Check for signs of wear or damage on isolators.
  • Ensure mounts are secure and functioning properly.
  • Replace any defective isolators or mounts as needed.
  • Flush the condensate lines with clean water.
  • Check pumps for proper operation and clear any blockages.
  • Inspect for any leaks in the condensate system.
  • Check each device according to manufacturer specifications.
  • Simulate conditions to ensure proper response from devices.
  • Document any failures and schedule repairs if needed.
  • Look for corrosion, leaks, or physical damage.
  • Ensure insulation is intact and properly installed.
  • Repair or replace any damaged piping as necessary.
  • Remove debris and dirt from the condenser coils.
  • Use a coil cleaner if necessary for stubborn buildup.
  • Rinse thoroughly and ensure coils are free of obstructions.
  • Check filters for dirt and debris accumulation.
  • Replace filters that are clogged or damaged.
  • Document filter replacement dates for maintenance records.
  • Use gauges to assess refrigerant levels.
  • Add or recover refrigerant according to specifications.
  • Ensure system is leak-free after adjustments.
  • Check for signs of wear or malfunction.
  • Test valve operation under normal conditions.
  • Adjust settings as necessary to ensure proper flow.
  • Run the compressor and listen for irregular sounds.
  • Check for proper startup and shutdown sequences.
  • Monitor temperature and pressure readings for anomalies.
  • Observe fan operation during normal functioning.
  • Ensure there are no obstructions to airflow.
  • Measure airflow to confirm it meets specifications.
  • Remove debris from the drain pan.
  • Ensure drain lines are clear and functioning properly.
  • Check for signs of algae or mold and clean thoroughly.
  • Test thermostat settings against actual temperatures.
  • Calibrate if discrepancies are found.
  • Ensure control signals are sent properly to the system.
  • Analyze logs for trends or unusual entries.
  • Identify any recurring issues that need attention.
  • Document findings for future reference.
  • Check wires, terminals, and connections for damage.
  • Look for discoloration or burn marks.
  • Replace any faulty components immediately.
  • Simulate alarm conditions to check response.
  • Verify that shutdown functions activate as intended.
  • Document any malfunctions for repair.
  • Compare current performance to baseline metrics.
  • Identify areas where efficiency could be improved.
  • Document evaluation results for future tracking.
  • Remove any leaves, dirt, or other blockages.
  • Ensure the unit has proper clearance from surrounding objects.
  • Inspect for signs of animal nesting or debris accumulation.
  • Check insulation for cracks, tears, or deterioration.
  • Replace any damaged insulation to prevent energy loss.
  • Ensure all insulation is securely attached.
  • Verify that there is adequate space around the unit.
  • Remove any obstacles that may impede airflow.
  • Document any issues with clearance for future reference.
  • Inspect all connections and surfaces for leaks.
  • Look for rust or corrosion on metal components.
  • Address any issues immediately to prevent system failure.

Annual Preventive Maintenance Checklist

  • Review previous semi-annual maintenance records.
  • Complete all tasks listed in the semi-annual checklist.
  • Ensure all components are functioning properly.
  • Document any issues found during the inspection.
  • Measure refrigerant levels using appropriate gauges.
  • Compare measurements to manufacturer specifications.
  • Replenish refrigerant if levels are low.
  • Check for leaks and repair as necessary.
  • Listen for unusual noises during operation.
  • Check for vibration or excessive heat.
  • Measure discharge and suction pressures.
  • Verify correct amperage draw against specifications.
  • Measure inlet and outlet temperatures.
  • Calculate the cooling capacity based on flow rates.
  • Assess system performance against manufacturer's data.
  • Identify areas for potential improvement.
  • Check for any signs of wear or damage.
  • Ensure insulation is securely fastened.
  • Replace any damaged or missing insulation.
  • Inspect joints and connections for proper sealing.
  • Review control system settings and parameters.
  • Check for software updates from the manufacturer.
  • Install updates if required.
  • Test system functionality post-update.
  • Examine the mounting and support framework.
  • Check for any signs of rust or corrosion.
  • Ensure all bolts and fasteners are tight.
  • Assess stability and alignment of the unit.
  • Go through the historical maintenance records.
  • Note any patterns or frequent problems.
  • Discuss findings with maintenance team.
  • Plan for addressing recurring issues.
  • Use a soft brush or vacuum to remove debris.
  • Check for bent fins and straighten them if needed.
  • Clean coils with a suitable cleaning solution.
  • Rinse thoroughly and ensure proper drainage.
  • Remove any visible debris from coils and pans.
  • Inspect drain lines for clogs or obstructions.
  • Use appropriate cleaners on coils.
  • Ensure proper water flow in drain pans.
  • Test all safety switches and alarms.
  • Simulate failure conditions to check response.
  • Document any discrepancies found.
  • Replace or repair faulty devices immediately.
  • Power off the system before inspection.
  • Check for loose or corroded connections.
  • Use a torque wrench on critical connections.
  • Clean terminals to ensure good conductivity.
  • Inspect fan blades for damage or wear.
  • Check motor operation and listen for unusual sounds.
  • Lubricate moving parts as per manufacturer guidelines.
  • Replace any damaged components.
  • Inspect belts for cracks, fraying, or glazing.
  • Check pulley alignment and tightness.
  • Replace belts showing signs of wear.
  • Document all findings in maintenance logs.
  • Use a vibration meter to assess levels.
  • Compare readings to baseline data.
  • Identify any abnormal vibrations.
  • Plan corrective actions if necessary.
  • Check valve seals for leaks.
  • Test actuator functionality if applicable.
  • Ensure expansion devices are operating within specifications.
  • Replace any faulty components.
  • Check calibration status against standards.
  • Test sensors and gauges for accuracy.
  • Recalibrate or replace as necessary.
  • Document calibration results.
  • Examine current emergency response procedures.
  • Identify any gaps or areas for improvement.
  • Update documentation based on new findings.
  • Conduct a review session with staff.
  • Inspect pumps for leaks and proper operation.
  • Check cooling towers for debris and water flow.
  • Ensure all auxiliary equipment is operational.
  • Document any issues for follow-up.
  • Assess the area for debris or obstacles.
  • Check for adequate airflow around the unit.
  • Remove any potential hazards.
  • Ensure compliance with safety regulations.
  • Use a standardized format for documentation.
  • Include details of inspections and repairs.
  • Store records in an accessible location.
  • Review documentation during future maintenance.
  • Prepare materials covering new procedures.
  • Schedule a session with all relevant staff.
  • Provide hands-on demonstrations if possible.
  • Encourage questions and feedback from staff.