Your checklists (
0
)
AI Checklist Generator
From the makers of
Manifestly Checklists
Sign in
Email address
Email me a magic link
Home
> nOBEL bIOCARE DRILLS USAGE CHART
nOBEL bIOCARE DRILLS USAGE CHART
Pre-Drilling Preparation
Check if all required drills are available
Ensure drills are sterilized and in good condition
Patient Information
Verify patient's name and identification number
Confirm the tooth/implant site for drilling
Drill Selection
Determine the appropriate drill size based on the surgical plan
Choose the correct drill type (e.g., twist drill, pilot drill, countersink drill)
Consider the specific anatomy and bone quality of the patient
Evaluate the desired implant size and position
Take into account any specific requirements or preferences of the patient or surgeon
Review the manufacturer's recommendations and guidelines for drill selection
Ensure the availability and proper sterilization of the chosen drill
Drill Sequence
Follow the recommended drill sequence provided by Nobel Biocare
Ensure each drill is used at the appropriate depth and speed
Clean and sterilize the drill before use
Check the drill for any damage or wear before use
Attach the appropriate drill bit to the handpiece
Place the drill bit perpendicular to the surgical site
Start the handpiece at the recommended speed
Apply gentle pressure and begin drilling
Monitor the drilling process and adjust speed if necessary
Remove the drill periodically to irrigate and cool the surgical site
Continue drilling until the desired depth is reached
Remove the drill from the surgical site and inspect the drill bit for any damage or wear
Repeat the drill sequence with the next recommended drill bit
Irrigation
Set up the irrigation system and ensure proper flow
Monitor irrigation throughout the drilling process to prevent overheating
Depth Control
Use depth stops or depth guides to maintain accurate drilling depth
Verify drilling depth periodically using depth markers or radiographs
Torque Control
Utilize a torque wrench to apply the recommended torque during drilling
Avoid excessive or insufficient torque, following manufacturer guidelines
Cooling Period
Allow sufficient time for the drill and surrounding bone to cool down
Minimize heat generation by using intermittent drilling and irrigation
Post-Drilling Evaluation
Inspect the drilled site for any signs of complications or issues
Check for bleeding or swelling
Look for any signs of infection or inflammation
Check for any damage to surrounding tissues
Document the drill sizes, depths, and any observed abnormalities
Record the size of each drill used
Note the depth reached with each drill
Document any irregularities or unexpected findings
Remember to adapt this checklist to your specific needs and consult the official Nobel Biocare Drills usage chart for detailed guidelines.
Check for proper seating of the implant in the drilled site
Ensure the implant is fully inserted into the prepared site
Check for any gaps or looseness
Confirm the implant is stable and secure
Evaluate the stability of the implant by performing a manual torque test
Apply gentle rotational force to the implant
Assess for any movement or instability
Ensure the implant can withstand normal chewing forces
Assess the surrounding bone for any signs of damage or fractures
Inspect the bone for cracks or fractures
Check for any signs of bone loss or resorption
Ensure the bone is healthy and intact
Verify the alignment and positioning of the implant using radiographic imaging
Take X-rays or other imaging scans to assess implant placement
Confirm proper alignment with adjacent teeth or implants
Check for any misplacement or angulation
Record any post-operative symptoms or discomfort reported by the patient
Document any pain, swelling, or sensitivity experienced
Note any difficulties in speaking or eating
Record any other concerns or issues reported
Discuss the post-drilling evaluation findings with the patient and address any concerns or questions they may have
Explain the results of the evaluation in a clear and understandable manner
Address any concerns or questions raised by the patient
Provide necessary reassurance or further instructions
Download CSV
Download JSON
Download Markdown
Use in Manifestly